LW36-145 Outdoor 40.5kV SF6 Circuit Breaker
LW36-145 Outdoor 40.5kV SF6 Circuit Breaker – Technical Description The LW36-145 is a high-performance outdoor circuit breaker designed for medium-voltage applications, rated at 40.5kV. It utilizes sulfur hexafluoride (SF6) gas as the insulating and arc-quenching medium, ensuring reliable operation under demanding conditions. This breaker is engineered for use in power distribution and transmission systems, providing protection against overloads, short circuits, and other electrical faults. Design and Construction The breaker features a robust, weatherproof enclosure constructed from high-strength materials to withstand harsh environmental conditions, including extreme temperatures, humidity, and pollution. Its compact, modular design simplifies installation and maintenance while ensuring long-term durability. The three-phase unit is typically mounted on a steel frame or integrated into a substation structure. SF6 Gas Insulation SF6 gas is used for its superior dielectric strength and excellent arc-extinguishing properties. The sealed gas system maintains consistent pressure, preventing external contaminants from affecting performance. Gas density monitoring ensures safe operation, with alarms or interlocks activated if pressure drops below the recommended threshold. Operating Mechanism The LW36-145 employs a spring-operated mechanism for quick, reliable switching. The energy-stored spring ensures fast opening and closing times, minimizing arcing duration and wear. The mechanism is designed for low maintenance, with self-lubricating components reducing friction and extending service life. Electrical Performance - Rated Voltage: 40.5kV - Rated Current: Up to 2500A (depending on configuration) - Short-Circuit Breaking Capacity: Typically 25kA–31.5kA - Dielectric Strength: Complies with IEC 62271 standards Applications This circuit breaker is ideal for substations, industrial plants, and renewable energy installations where reliable fault interruption is critical. Its outdoor design eliminates the need for additional housing, reducing infrastructure costs. Safety and Maintenance The LW36-145 includes safety features such as pressure relief devices and gas leakage detection. Routine maintenance involves visual inspections, gas pressure checks, and mechanism testing. The breaker’s modular design allows for easy component replacement. Conclusion The LW36-145 40.5kV SF6 circuit breaker combines advanced technology with rugged construction, delivering high reliability and efficiency in medium-voltage power systems. Its SF6 insulation, robust mechanism, and low-maintenance design make it a preferred choice for utilities and industries worldwide.
Products
Category:
-
LW36-145 Outdoor SF6 Circuit Breaker High Voltage 40.5kV Automatic Power Distribution Equipment For Substation Electrical Protection
Category: SF6 Circuit BreakerBrowse number: 1276Number:Release time: 2025-08-30 09:40:12The LW36-145 Outdoor SF6 Circuit Breaker 40.5kV delivers reliable and durable electrical protection for substations and power distribution networks. Designed for automatic switching and high-voltage operations, it ensures efficient fault interruption, safe load management, and long service life, making it an ideal solution for critical outdoor power distribution infrastructure.
News
Category:
No search results found!
Case
Category:
No search results found!
Exhibition
Category:
No search results found!
Download
Category:
No search results found!
Job
Category:
No search results found!
Featured Products
No search results found!






Phone